Independent fire investigation · NFPA 921

Origin & cause · Pan-India

Every fire leaves evidence. We find it.

Zuber & Co. establishes where a fire started, how it spread and why — for industry, insurers and the courts.

Scene documentation — post-fire examination Scroll to investigate
  • Origin & cause
  • Industrial & process
  • Automotive
  • Wildland
  • Litigation support
Casework across
  • Range Rover
  • Lamborghini
  • Mercedes-Benz
  • BMW
  • Hyundai
  • Kia
  • Pharma
  • Solar
  • Thermal power
  • Textile
  • FGD plants

The work

A fire destroys the evidence. Then the arguments begin.

Charred storage racks and collapsed steel shelving inside a warehouse after a fire
Post-fire examination Warehouse interior

By the time a claim is filed, the scene has been hosed down, cleared, and rebuilt in a dozen different accounts. We arrive early, document what is still standing, and read it back from first principles.

Every report is built to survive cross-examination: measured, photographed and tested against NFPA 921 — then stated in language a court can follow.

How we establish a cause

Origin & cause

A defensible point of origin and a cause that holds — not a guess dressed as a conclusion.

Failure analysis

Which component failed, in what sequence, and what the damage pattern proves about it.

Claim & court support

Independent findings for insurers, surveyors and counsel — with the evidence trail behind them.

Field record

The scene is the argument.

Selected documentation from fire scenes we have examined — aerial survey, structural damage, fuel load and component failure.

Aerial view of a smouldering industrial warehouse with smoke drifting across the roof
Smoke travel mapped from above Industrial warehouse
Overhead view of a collapsed metal roof after a factory fire
Collapse, burn pattern retained Process building
Aerial view of a burned factory unit and surrounding land
Perimeter and spread surveyed from the air Site approach
Burned pallets and charred stock in a storage bay
Char depth and fuel load Storage bay
Fire-damaged sports car in a workshop with the front section destroyed
Engine-bay origin Vehicle fire

Method

The method is the argument.

Fire investigation is a science before it is an opinion. We follow the NFPA 921 scientific method — seven steps, in order, every time.

Close view of fire-damaged process machinery and debris on a factory floor
Component-level failure Process equipment

A cause is only as strong as the process behind it. Each stage is documented, and every hypothesis is tested against the physical evidence before it reaches a report.

A loss has occurred and a decision depends on its cause: a claim, a dispute, a safety change. We define what must be answered before anyone touches the scene.

The question is framed precisely — origin, cause, spread or component failure — so the examination has a measurable target.

Scene documentation, photography, witness accounts, maintenance and electrical records, fire service reports and physical samples.

Burn patterns, arc mapping, damage gradients and material behaviour are read together — never in isolation.

A probable explanation is formed from the evidence on the ground — never from the outcome a client would prefer.

Every hypothesis is tested against the physical evidence. Explanations that fail the test are discarded, whatever they cost.

The conclusion that survives scrutiny is reported with its basis, its limits and the evidence that supports it.

Every conclusion is tested against NFPA 921 — the recognised standard for fire and explosion investigations.

Field footage

What the camera recorded.

Recorded on site — vehicles, wildland, plant and structure, exactly as the evidence was found.

Roadside vehicle fire

Scene recording · 0:40
01 / 05

Fire decoded

The case files, on video.

Judgements, claim disputes and fire science — explained from real investigations on our YouTube channel. The latest uploads appear here automatically.

Visit the channel
Fire decoded

Case studies, claim disputes and fire science, straight from the channel.

Open the channel
Loading the latest uploads…

The channel feed could not be reached right now.

Aerial view of a burned factory unit next to a canal and neighbouring buildings
Site documentation Secunderabad

Why Zuber & Co.

Built for the questions that come after the fire.

A fire report is read by people who did not see the scene and who have every reason to disagree with it. It has to stand on its own.

Independent

No retainer from insurers, manufacturers or contractors. The report follows the evidence, not the outcome.

NFPA 921 grounded

Every finding is tested against the recognised scientific method for fire and explosion investigation.

Court-ready

Reports written to be read aloud, cross-examined and defended — not simply filed.

Pan-India reach

Scene deployments across India, with case material explained in English and regional languages.

Industries
  • Pharma
  • Solar
  • Thermal power
  • Textile
  • Automotive
  • Logistics
  • Chemicals
  • FGD plants

Next step

Bring us the ashes. We'll bring the answers.

Tell us what burned, when, and what is at stake. We will tell you what can still be established — and how quickly we can be on site.

Office Plot No. 13, Anjum Mansion,
Sikh Village, Tarnaka,
Secunderabad 500009, India

For an active scene, call directly. Early documentation protects the evidence.